5915-00-899-0708 FILTER,BAND PASS Index 5915-00-899-0711 FILTER,BAND PASS

National Stock Number:
5915-00-899-0710

Federal Supply Class:
5915

National Item Identification Number:
008990710

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
188148703956NORTHROP GRUMMAN SYSTEMS CORPORATION
MPP2608040AMERICAN BUSINESS ALLIANCE, INC. JEREMY MADVIN DBA OMNI WAVE
P189543603956NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION5.0 KILOWATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
CUBIC MEASURE179.0 CUBIC INCHES
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND 27.0 MINIMUM BLANK AND 20.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH15.375 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CIRCULAR FLANGE OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CIRCULAR FLANGE INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION400.00 MEGAHERTZ BLANK AND 450.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEUNINCLOSED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.25 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY2 FLANGE LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION425.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
UNPACKAGED UNIT WEIGHT2.500 POUNDS NOMINAL
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION400.0 MEGAHERTZ BLANK AND 450.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION400.00 MEGAHERTZ BLANK AND 450.00 MEGAHERTZ BLANK AND 800.00 MEGAHERTZ BLANK AND 2.25 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED