5325-00-881-5066 STUD ASSEMBLY,TURNLOCK FASTENER Index 6615-00-881-5068 CONTROLLER,AUTOPILO

National Stock Number:
5915-00-881-5067

Federal Supply Class:
5915

National Item Identification Number:
008815067

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
713810-04405869RAYTHEON COMPANY
713810-4405869RAYTHEON COMPANY
WFV313900853CORNELL-DUBILIER MARKETING INC
WFV313914655CORNELL-DUBILIER ELECTRONICS
SMC41679318876U S ARMY AVIATION AND MISSILE COMMAND
BP59280294BOURNS INSTRUMENTS INC


Techincal Specification:
BODY HEIGHT4.500 INCHES MAXIMUM
BODY MATERIALMETAL
BODY LENGTH4.750 INCHES MAXIMUM
BODY WIDTH2.500 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS AND 30.0 MINIMUM 2ND BAND PASS SECOND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.740 INCHES MINIMUM AND 1.760 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.990 INCHES MINIMUM AND 4.010 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY6 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.10 KILOHERTZ 2ND BAND PASS AND 1.90 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION500.00 HERTZ 1ST BAND PASS AND 700.00 HERTZ 1ST BAND PASS FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD20.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
INPUT IMPEDANCE PER FUNCTION W/LOAD20.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 1ST BAND PASS FIRST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.5 2ND BAND PASS SECOND FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT2.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT2.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
OVERALL HEIGHT5.000 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.164 INCHES
OPERATING TEMP RANGE-55.0 TO 65.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION1.5 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION600.0 HERTZ 1ST BAND PASS FIRST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION300.00 HERTZ 1ST BAND PASS AND 500.00 HERTZ 1ST BAND PASS AND 700.00 HERTZ 1ST BAND PASS AND 1.00 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION600.00 HERTZ 2ND BAND PASS AND 1.10 KILOHERTZ 2ND BAND PASS AND 1.90 KILOHERTZ 2ND BAND PASS AND 2.40 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE