5915-00-860-5702 FILTER,HIGH PASS Index 5950-00-860-5704 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5915-00-860-5703

Federal Supply Class:
5915

National Item Identification Number:
008605703

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
12021817304DAMON CORP ELECTRONICS DIV
378A397H02REVA97942NORTHROP GRUMMAN SYSTEMS CORPORATION
385L28726BULOVA TECHNOLOGIES L.L.C. DBA ENVIRONMENTAL SYSTEMS & SVCS


Techincal Specification:
AVERAGE LIFE RATING IN HOURS40000.0
BODY HEIGHT1.906 INCHES NOMINAL
BODY LENGTH4.375 INCHES NOMINAL
BODY WIDTH2.375 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS2.0 MAXIMUM BLANK AND 50.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.688 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.688 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.9925 MEGAHERTZ BLANK AND 1.9997 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.719 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.9961 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.9925 MEGAHERTZ BLANK AND 1.9997 MEGAHERTZ BLANK AND 2.0003 MEGAHERTZ BLANK FIRST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE