5950-00-827-7179 TRANSFORMER,AUDIO FREQUENCY Index 5950-00-827-7181 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5915-00-827-7180

Federal Supply Class:
5915

National Item Identification Number:
008277180

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
77C709227-103538LOCKHEED MARTIN CORPORATION
77C709227P00103538LOCKHEED MARTIN CORPORATION
77C709227P103538LOCKHEED MARTIN CORPORATION


Techincal Specification:
BODY HEIGHT3.250 INCHES NOMINAL
BODY LENGTH3.031 INCHES MAXIMUM
BODY WIDTH3.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 NOMINAL BLANK AND 25.0 NOMINAL BLANK AND 50.0 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.984 INCHES MINIMUM AND 2.016 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.984 INCHES MINIMUM AND 2.016 INCHES MAXIMUM
FREQUENCY BAND WIDTH PER FUNCTION85.00 HERTZ BLANK AND 215.00 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD GROUND FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD OUTPUT THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD INPUT SECOND FUNCTION
INCLOSURE TYPEENCAPSULATED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION1.070 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
OVERALL HEIGHT3.750 INCHES NOMINAL
REFERENCE FREQUENCY PER FUNCTION150.0 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION85.00 HERTZ BLANK AND 215.00 HERTZ BLANK AND 350.00 HERTZ BLANK AND 500.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE