5915-00-826-9317 FILTER,RADIO FREQUENCY INTERFERE Index 5998-00-826-9320 ELECTRONIC COMPONENTS ASSEMBLY

National Stock Number:
5915-00-826-9318

Federal Supply Class:
5915

National Item Identification Number:
008269318

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
335C841H0379500WESTINGHOUSE ELECTRIC CORP
335C841H0397942NORTHROP GRUMMAN SYSTEMS CORPORATION
JN17-323A56289SPRAGUE ELECTRIC CO WORLD HQS


Techincal Specification:
BODY LENGTH11.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH8.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH6.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH12.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OVERALL HEIGHT2.562 INCHES NOMINAL
OVERALL LENGTH13.000 INCHES NOMINAL
OVERALL WIDTH10.880 INCHES NOMINAL
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY6 SLOT LOCATION NOT OTHERWISE SPECIFIED
MOUNTING SLOT WIDTH0.266 INCHES NOMINAL
OPERATING CURRENT RATING PER FUNCTION IN AMPS125.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS125.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS125.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES