5915-00-825-9647 FILTER,BAND PASS Index 5930-00-825-9654 SWITCH,THERMOSTATIC

National Stock Number:
5915-00-825-9648

Federal Supply Class:
5915

National Item Identification Number:
008259648

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
241-0277-00013499ROCKWELL COLLINS, INC.
502082268SPARTON CORPORATION
X050-281815COMMUNICATION COIL, INC.


Techincal Specification:
BODY HEIGHT1.141 INCHES NOMINAL
BODY LENGTH3.172 INCHES MINIMUM AND 3.219 INCHES MAXIMUM
BODY WIDTH1.141 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 6.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.968 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
FREQUENCY BAND WIDTH PER FUNCTION4.49 MEGAHERTZ BLANK AND 4.71 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATION27-90
INPUT TERMINAL MANUFACTURER CODE74868
INPUT IMPEDANCE PER FUNCTION W/LOAD8.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 75.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT350.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATION27-90
OUTPUT TERMINAL MANUFACTURER CODE74868
REFERENCE FREQUENCY PER FUNCTION4.6 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION4.00 MEGAHERTZ BLANK AND 4.49 MEGAHERTZ BLANK AND 4.71 MEGAHERTZ BLANK AND 5.20 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0


Click here to Register for Free 30-day Trial