5915-00-801-3389 FILTER,RADIO FREQUENCY INTERFERE Index 5950-00-801-3393 TRANSFORMER,POWER

National Stock Number:
5915-00-801-3390

Federal Supply Class:
5915

National Item Identification Number:
008013390

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
4400B0158ISSUE287557LOCKHEED CORP LOCKHEED ELECTRONICS CO INC
4400B0158ISSUE294117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
FA427413619EMS DEVELOPMENT CORPORATION
FA427481831FILTRON CO INC DIV OF RFI CORP


Techincal Specification:
BODY LENGTH8.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH3.688 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES MINIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT3.688 INCHES NOMINAL
OVERALL LENGTH10.750 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S) SECOND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) FIRST FUNCTION
NOMINAL THREAD SIZE0.250 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION500.0 VOLTS AC BLANK AND 1.0 KILOVOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
UNTHREADED MOUNTING HOLE DIAMETER0.228 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial