4540-00-726-4386 HEATING ELEMENT,ELECTRICAL,NONIMMERSION TYPE Index 5945-00-726-4388 RELAY,ELECTROMAGNETIC

National Stock Number:
5915-00-726-4387

Federal Supply Class:
5915

National Item Identification Number:
007264387

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
152A662H0179500WESTINGHOUSE ELECTRIC CORP
152A662H0197942NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
BODY HEIGHT3.060 INCHES NOMINAL
BODY LENGTH2.250 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH2.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND 50.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.690 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.440 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION0.00 HERTZ BLANK AND 3.50 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT3.440 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
REFERENCE FREQUENCY PER FUNCTION1.75 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION0.00 HERTZ BLANK AND 3.50 KILOHERTZ BLANK AND 5.00 KILOHERTZ BLANK AND 10.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial