5935-00-717-5408 CONNECTOR,PLUG,ELECTRICAL Index 4935-00-717-5411 COVER,PROTECTIVE,SY

National Stock Number:
5915-00-717-5409

Federal Supply Class:
5915

National Item Identification Number:
007175409

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
104953759364HONEYWELL INTERNATIONAL INC.
104953777068ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO ELECTRODYNAMICS DIV
F1L0085-00022929DALE ELECTRONICS INC FREQUENCY CONTROL GROUP
FW10AT100KC75378CTS INC
F1L0085-00082567CTS REEVES FREQUENCY PRODUCTS


Techincal Specification:
BODY HEIGHT2.190 INCHES MAXIMUM
BODY LENGTH4.000 INCHES MAXIMUM
BODY WIDTH1.310 INCHES MINIMUM AND 1.370 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS55.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION99.775 KILOHERTZ BLANK AND 100.225 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD500.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.8 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION27.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE-30.0 TO 55.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.670 INCHES MINIMUM
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION100.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION27.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION99.30 KILOHERTZ BLANK AND 99.77 KILOHERTZ BLANK AND 100.23 KILOHERTZ BLANK AND 100.78 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE