5915-00-583-1963 FILTER,BAND PASS Index 5915-00-583-1966 FILTER,BAND PASS

National Stock Number:
5915-00-583-1964

Federal Supply Class:
5915

National Item Identification Number:
005831964

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
526-9311-0013499ROCKWELL COLLINS, INC.
526-9311-0055097SHILOH INDUSTRIES INC
526-9311-00013499ROCKWELL COLLINS, INC.
526-9311-00213499ROCKWELL COLLINS, INC.
526-9311-0095105ROCKWELL COLLINS, INC.
526-9311-00095105ROCKWELL COLLINS, INC.
F300Z513499ROCKWELL COLLINS, INC.
F300Z595105ROCKWELL COLLINS, INC.
526-9311-00295105ROCKWELL COLLINS, INC.


Techincal Specification:
BODY LENGTH3.469 INCHES MINIMUM AND 3.531 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.760 INCHES MINIMUM AND 0.790 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 2.5 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE HOOK INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE HOOK OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION297.00 KILOHERTZ BLANK AND 299.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD35.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS15.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-40.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT35.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH4.093 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT ALTITUDE
REFERENCE FREQUENCY PER FUNCTION300.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION295.80 KILOHERTZ BLANK AND 297.00 KILOHERTZ BLANK AND 299.65 KILOHERTZ BLANK AND 301.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
TEST DATA DOCUMENT13499-526-9311-00 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Click here to Register for Free 30-day Trial