5915-00-581-6284 FILTER,RADIO FREQUENCY INTERFERE Index 5905-00-581-6288 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5915-00-581-6285

Federal Supply Class:
5915

National Item Identification Number:
005816285

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
64-8822-0104423TELONIC BERKELEY, INC.
6BP1200-52-4SS104423TELONIC BERKELEY, INC.
FBT2-1200-50-4-50-28A28A23042TRILITHIC, INC.
711437-196214RAYTHEON COMPANY


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
AVERAGE POWER RATING PER FUNCTION0.5 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS35.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.175 GIGAHERTZ BLANK AND 1.225 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATION28A
INPUT TERMINAL MANUFACTURER CODE21377
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 70.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATION28A
OUTPUT TERMINAL MANUFACTURER CODE21377
OVERALL LENGTH4.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY1 CLAMP LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONELECTROMECHANICAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.2 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.2 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.10 GIGAHERTZ BLANK AND 1.175 GIGAHERTZ BLANK AND 1.225 GIGAHERTZ BLANK AND 1.30 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial