5950-00-528-9268 COIL,RADIO FREQUENCY Index 5950-00-528-9272 TRANSFORMER,POWER

National Stock Number:
5915-00-528-9270

Federal Supply Class:
5915

National Item Identification Number:
005289270

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6091374-103640LOCKHEED MARTIN CORPORATION
F4BC125-34PP23042TRILITHIC, INC.


Techincal Specification:
BODY HEIGHT0.500 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.025 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS10.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.025 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.525 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION108.00 MEGAHERTZ BLANK AND 142.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.625 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY5 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION125.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION108.0 MEGAHERTZ BLANK AND 142.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.3 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION74.00 MEGAHERTZ BLANK AND 108.00 MEGAHERTZ BLANK AND 142.00 MEGAHERTZ BLANK AND 176.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE