3130-00-522-6903 HOUSING,BEARING UNIT Index 8145-00-522-6907 SHIPPING AND STORAGE CONTAINER

National Stock Number:
5915-00-522-6905

Federal Supply Class:
5915

National Item Identification Number:
005226905

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
101449-0135351GE AVIATION SYSTEMS LLC
1734A31435LUCAS AEROSPACE POWER EQUIPMENT CORPORATION
5003-000113050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
1734A35351GE AVIATION SYSTEMS LLC
1734A3CPE0SAFRAN POWER USA LLC


Techincal Specification:
BODY HEIGHT2.218 INCHES MINIMUM AND 2.281 INCHES MAXIMUM
BODY LENGTH1.968 INCHES MINIMUM AND 2.031 INCHES MAXIMUM
BODY WIDTH1.500 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.875 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONGS02-14S-7P
INPUT TERMINAL MANUFACTURER CODE71468
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH3.765 INCHES MAXIMUM
MAXIMUM VOLTAGE DROP PER FUNCTION0.75 MILLIVOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY3 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING TEMP RANGE-65.0 TO 165.0 FAHRENHEIT
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
OUTPUT TERMINAL IDENTIFICATIONAN3106A-14S-7S
OUTPUT TERMINAL MANUFACTURER CODE96906
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.157 INCHES NOMINAL