4820-00-504-8059 PARTS KIT,VALVE Index 5915-00-504-8065 FILTER,HIGH PASS

National Stock Number:
5915-00-504-8064

Federal Supply Class:
5915

National Item Identification Number:
005048064

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1622405584AUTODYNE MANUFACTURING CO INC
1622480089EMERSON ELECTRIC CO WHITE-RODGERS DIV
SM-C-14376480063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.312 INCHES MAXIMUM
BODY LENGTH1.391 INCHES MAXIMUM
BODY WIDTH1.391 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.5 MAXIMUM BLANK AND 30.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.875 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.875 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION300.00 HERTZ BLANK AND 3.50 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-40.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.656 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
REFERENCE FREQUENCY PER FUNCTION1.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION300.00 HERTZ BLANK AND 3.50 KILOHERTZ BLANK AND 5.50 KILOHERTZ BLANK AND 11.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE