5975-00-504-8039 BRIDLE RING Index 5920-00-504-8045 FUSE,CARTRIDGE

National Stock Number:
5915-00-504-8041

Federal Supply Class:
5915

National Item Identification Number:
005048041

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1589100781CESSNA AIRCRAFT CO ARC AVIONICS DIV
H200115634MAGNETIKA INC
H200180223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC


Techincal Specification:
BODY HEIGHT1.625 INCHES NOMINAL
BODY LENGTH1.688 INCHES NOMINAL
BODY WIDTH1.188 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.969 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION142.00 HERTZ BLANK AND 158.00 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD8.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT1.5 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.875 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE1.0 KILOVOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.0 KILOVOLTS AT SEA LEVEL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION150.0 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION90.00 HERTZ BLANK AND 142.00 HERTZ BLANK AND 158.00 HERTZ BLANK AND 250.00 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE