| BODY LENGTH | 2.160 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY WIDTH | 0.340 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.860 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET GROUND THIRD FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET OUTPUT SECOND FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET INPUT FIRST FUNCTION |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| NOMINAL THREAD SIZE | 0.086 INCHES |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| SPECIAL FEATURES | 14 SECTIONS |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |