5905-00-480-1733 RESISTOR,FIXED,FILM Index 5950-00-480-1736 COIL,RADIO FREQUENCY

National Stock Number:
5915-00-480-1734

Federal Supply Class:
5915

National Item Identification Number:
004801734

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
292117P194117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
292117P494117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS2000.0
BODY HEIGHT1.380 INCHES NOMINAL
BODY LENGTH3.080 INCHES NOMINAL
BODY WIDTH0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS45.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.840 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 RECEPTACLE, COAXIAL INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 RECEPTACLE, COAXIAL OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION4.10 GIGAHERTZ BLANK AND 6.05 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 125.0 CELSIUS
OVERALL HEIGHT1.760 INCHES NOMINAL
OVERALL LENGTH3.080 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED HOLE(S) SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION5.075 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+30.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION4.1 GIGAHERTZ BLANK AND 6.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION3.95 GIGAHERTZ BLANK AND 4.10 GIGAHERTZ BLANK AND 6.05 GIGAHERTZ BLANK AND 6.19 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES


Click here to Register for Free 30-day Trial