5315-00-450-0097 PIN,STRAIGHT,HEADLESS Index 5915-00-450-0100 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-00-450-0099

Federal Supply Class:
5915

National Item Identification Number:
004500099

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
A44196-142498DAR ELECTRONICS INC DBA NATIONAL RADIO CO


Techincal Specification:
BODY HEIGHT2.219 INCHES MINIMUM AND 2.250 INCHES MAXIMUM
BODY LENGTH4.344 INCHES MINIMUM AND 4.375 INCHES MAXIMUM
BODY WIDTH2.969 INCHES MINIMUM AND 3.000 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATION8003-14S7PFR
INPUT TERMINAL MANUFACTURER CODE97814
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.164 INCHES
OPERATING TEMP RANGE+0.0 TO 85.0 CELSIUS
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC BLANK AND 600.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.719 INCHES MINIMUM AND 2.750 INCHES MAXIMUM
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE