5915-00-441-9417 NETWORK,PULSE FORMING Index 5325-00-441-9424 INSERT,SCREW THREAD

National Stock Number:
5915-00-441-9418

Federal Supply Class:
5915

National Item Identification Number:
004419418

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
211XS32918RYKA SCIENTIFIC INC
SM-A-70127980063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.040 INCHES MAXIMUM
BODY LENGTH2.040 INCHES MAXIMUM
BODY MATERIALMETAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION8.87 GIGAHERTZ BLANK AND 9.03 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATIONOSM FEMALE
INPUT TERMINAL MANUFACTURER CODE80063
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONOSM FEMALE
OUTPUT TERMINAL MANUFACTURER CODE80063
OVERALL LENGTH3.200 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION9.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION8.87 GIGAHERTZ BLANK AND 9.03 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION8.00 GIGAHERTZ BLANK AND 8.87 GIGAHERTZ BLANK AND 9.03 GIGAHERTZ BLANK AND 10.50 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES