| BODY LENGTH | 1.125 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.406 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OVERALL LENGTH | 1.530 INCHES MAXIMUM |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 5.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING THIRD FUNCTION |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| NOMINAL THREAD SIZE | 0.250 INCHES |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |
| TEST DATA DOCUMENT | 06481-905476 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |