3020-00-430-2568 GEAR,SPUR Index 5950-00-430-2584 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5915-00-430-2582

Federal Supply Class:
5915

National Item Identification Number:
004302582

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
9001-516-1010B0LSP2SPECTRUM CONTROL, INC.
9001-516-1010B12294MURATA ERIE NORTH AMERICA INC DIVOF MURATA ERIE
9001-700-101012294MURATA ERIE NORTH AMERICA INC DIVOF MURATA ERIE
CSFD47619193COIL SPECIALTY COMPANY, INC.
D47650056PIEZOTHERMX CORPORATION
930426-7B82577RAYTHEON COMPANY
D47651642CENTRE CAPACITOR INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS1000.0
BODY LENGTH0.598 INCHES MAXIMUM
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.375 INCHES NOMINAL
BODY SURFACE TREATMENTTIN
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FEATURES PROVIDEDNUT AND WASHER
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.03 AND 0.15 AND 0.3 AND 1.0 AND 10.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS15.0 AND 50.0 AND 68.0 AND 82.0
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION150.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH1.138 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE200.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION1.5 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MAXIMUM TEMP RISE25.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING THIRD FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.250 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
UNPACKAGED UNIT WEIGHT8.500 GRAMS NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES