5930-00-410-1714 SWITCH CONTROL Index 5915-00-410-1719 FILTER,LOW PASS

National Stock Number:
5915-00-410-1717

Federal Supply Class:
5915

National Item Identification Number:
004101717

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
TLC20-3EF104423TELONIC BERKELEY, INC.


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION15.0 MEGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.47 BLANK
FREQUENCY BAND WIDTH PER FUNCTION10.00 MEGAHERTZ BLANK AND
20.00 MEGAHERTZ BLANK
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION10.0 MEGAHERTZ BLANK AND
20.0 MEGAHERTZ BLANK
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
BODY OUTSIDE DIAMETER1.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION10.00 MEGAHERTZ BLANK AND
20.00 MEGAHERTZ BLANK AND
35.50 MEGAHERTZ BLANK AND
39.50 MEGAHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS0.53 NOMINAL BLANK AND
0.41 NOMINAL BLANK AND
40.0 MINIMUM BLANK AND
50.0 MINIMUM BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
INPUT TERMINAL MANUFACTURER CODE11882
INPUT TERMINAL IDENTIFICATION31708
OUTPUT TERMINAL MANUFACTURER CODE11882
OUTPUT TERMINAL IDENTIFICATION31709
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
OPERATING TEMP RANGE-20.0 TO 50.0 DEG CELSIUS


Click here to Register for Free 30-day Trial