1560-00-403-1415 FITTING,LINE SUPPORT Index 5915-00-403-1417 FILTER,BAND PASS

National Stock Number:
5915-00-403-1416

Federal Supply Class:
5915

National Item Identification Number:
004031416

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
60912-182340L3HARRIS TECHNOLOGIES, INC.
60912-19Y580L3HARRIS TECHNOLOGIES, INC.
B137408715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC


Techincal Specification:
BODY HEIGHT0.625 INCHES MAXIMUM
BODY LENGTH1.700 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.700 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION10.00 KILOHERTZ BLANK AND 16.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS9.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OVERALL HEIGHT0.760 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY6 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION13.1 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION3.00 KILOHERTZ BLANK AND 10.00 KILOHERTZ BLANK AND 16.00 KILOHERTZ BLANK AND 50.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE