| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 7.380 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 8.750 INCHES NOMINAL |
| AVERAGE POWER RATING PER FUNCTION | 2.0 WATTS 2ND RADIO INTERFERENCE |
| AVERAGE POWER RATING PER FUNCTION | 2.0 WATTS 3RD RADIO INTERFERENCE |
| AVERAGE POWER RATING PER FUNCTION | 2.0 WATTS 1ST RADIO INTERFERENCE |
| BODY HEIGHT | 8.000 INCHES NOMINAL |
| BODY LENGTH | 26.000 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY SURFACE TREATMENT | TIN |
| BODY WIDTH | 8.000 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT 1ST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT 2ND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.0 KILOVOLTS AT SEA LEVEL |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
| PROPRIETARY CHARACTERISTICS | PACS |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 3RD RADIO INTERFERENCE |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 2ND RADIO INTERFERENCE |
| MAXIMUM TEMP RISE | 125.0 DEG CELSIUS |
| MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 1ST RADIO INTERFERENCE |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 2ND RADIO INTERFERENCE |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 3RD RADIO INTERFERENCE |
| OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| OVERALL LENGTH | 28.000 INCHES NOMINAL |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| UNPACKAGED UNIT WEIGHT | 24.000 POUNDS |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL |