5915-00-400-1813 FILTER,RADIO FREQUENCY INTERFERE Index 5935-00-400-1818 CONNECTOR,PLUG,ELECTRICAL

National Stock Number:
5915-00-400-1816

Federal Supply Class:
5915

National Item Identification Number:
004001816

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
E-171423160LINDGREN RF ENCLOSURES INC ELMAG DIV
RF0075613619EMS DEVELOPMENT CORPORATION
RF75613619EMS DEVELOPMENT CORPORATION
RF756 1361913619EMS DEVELOPMENT CORPORATION
SP10724432ARITECH CORP


Techincal Specification:
BODY LENGTH3.500 INCHES MINIMUM AND 3.620 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.115 INCHES MINIMUM AND 1.145 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH4.000 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.2 KILOVOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC BLANK AND 6.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.437 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION600.0 VOLTS AC BLANK AND 250.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES