3040-00-322-9188 GEARSHAFT,SPUR Index 5820-00-322-9193 RECEIVER,RADIO

National Stock Number:
5915-00-322-9192

Federal Supply Class:
5915

National Item Identification Number:
003229192

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
ES158-00580045L3HARRIS CINCINNATI ELECTRONICS CORPORATION


Techincal Specification:
BODY HEIGHT0.550 INCHES NOMINAL
BODY LENGTH2.750 INCHES NOMINAL
BODY WIDTH0.850 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.800 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.200 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION454.90 KILOHERTZ BLANK AND 455.10 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.900 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD(S) FIRST FUNCTION
OPERATING TEMP RANGE-40.0 TO 131.0 FAHRENHEIT
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION455.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+20.0 TO 2000.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION454.60 KILOHERTZ BLANK AND 454.90 KILOHERTZ BLANK AND 455.10 KILOHERTZ BLANK AND 455.40 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial