5895-00-304-4548 PATCH BAY,PRIMARY VOICE FREQUENCY Index 5915-00-304-4553 FILTER,BAND PASS

National Stock Number:
5915-00-304-4552

Federal Supply Class:
5915

National Item Identification Number:
003044552

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
37253880045L3HARRIS CINCINNATI ELECTRONICS CORPORATION


Techincal Specification:
BODY HEIGHT0.500 INCHES NOMINAL
BODY LENGTH2.000 INCHES NOMINAL
BODY WIDTH0.750 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS45.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.328 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.187 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION10.99 MEGAHERTZ BLANK AND 11.01 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEUNINCLOSED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-40.0 TO 80.0 CELSIUS
OVERALL HEIGHT0.656 INCHES NOMINAL
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION11.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+20.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION10.99 MEGAHERTZ BLANK AND 11.01 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION10.55 MEGAHERTZ BLANK AND 10.99 MEGAHERTZ BLANK AND 11.01 MEGAHERTZ BLANK AND 11.45 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE