5915-00-281-0277 FILTER,BAND PASS Index 5915-00-281-0279 FILTER,BAND PASS

National Stock Number:
5915-00-281-0278

Federal Supply Class:
5915

National Item Identification Number:
002810278

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1800-118212AMERICAN TRANS-COIL CORP
GA5057464959AMERICAN TELEPHONE AND TELEGRAPH CO
SC-C-6253180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.594 INCHES NOMINAL
BODY LENGTH6.031 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.438 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS38.0 MINIMUM BLANK AND 8.5 MAXIMUM BLANK AND 58.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.812 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION12.50 KILOHERTZ BLANK AND 15.70 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-65.0 TO 185.0 FAHRENHEIT
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.969 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
REFERENCE FREQUENCY PER FUNCTION14.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION12.00 KILOHERTZ BLANK AND 12.50 KILOHERTZ BLANK AND 15.70 KILOHERTZ BLANK AND 20.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial