5915-00-281-0266 FILTER,BAND PASS Index 5915-00-281-0268 FILTER,BAND PASS

National Stock Number:
5915-00-281-0267

Federal Supply Class:
5915

National Item Identification Number:
002810267

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
40978-173386FREED TRANSFORMER CO
ELRC106013571ELECTRONIC RESEARCH CO SUB OF Q-TECH CORP
GA5116564959AMERICAN TELEPHONE AND TELEGRAPH CO
SC-C-6342673386FREED TRANSFORMER CO
SC-C-6342680063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.594 INCHES NOMINAL
BODY LENGTH3.031 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.438 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS65.0 MINIMUM BLANK AND 2.5 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.812 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION67.00 KILOHERTZ BLANK AND 69.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD135.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-65.0 TO 185.0 FAHRENHEIT
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT135.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.969 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION68.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION52.00 KILOHERTZ BLANK AND 67.00 KILOHERTZ BLANK AND 69.00 KILOHERTZ BLANK AND 84.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial