5915-00-281-0261 FILTER,BAND PASS Index 5915-00-281-0263 FILTER,BAND PASS

National Stock Number:
5915-00-281-0262

Federal Supply Class:
5915

National Item Identification Number:
002810262

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
GA5021264959AMERICAN TELEPHONE AND TELEGRAPH CO
SC-C-6317180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.594 INCHES NOMINAL
BODY LENGTH6.031 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.438 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS65.0 MINIMUM BLANK AND 6.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.688 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION92.00 KILOHERTZ BLANK AND 108.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD135.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.7 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-65.0 TO 185.0 FAHRENHEIT
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT135.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.969 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION100.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION70.00 KILOHERTZ BLANK AND 92.00 KILOHERTZ BLANK AND 108.00 KILOHERTZ BLANK AND 130.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE