5915-00-281-0251 FILTER,BAND PASS Index 5915-00-281-0253 FILTER,BAND PASS

National Stock Number:
5915-00-281-0252

Federal Supply Class:
5915

National Item Identification Number:
002810252

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
A801205584AUTODYNE MANUFACTURING CO INC
CC1615-0032840CONOLOG CORPORATION
GA5021864959AMERICAN TELEPHONE AND TELEGRAPH CO
SC-C-6342280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.594 INCHES NOMINAL
BODY LENGTH2.531 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.438 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS50.0 MINIMUM BLANK AND 14.7 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.312 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION15.80 KILOHERTZ BLANK AND 16.20 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD135.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS14.7 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-65.0 TO 185.0 FAHRENHEIT
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT40.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT3.094 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION16.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION12.00 KILOHERTZ BLANK AND 15.80 KILOHERTZ BLANK AND 16.20 KILOHERTZ BLANK AND 20.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE