5310-00-275-0327 NUT,PLAIN,HEXAGON Index 5915-00-275-0329 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-00-275-0328

Federal Supply Class:
5915

National Item Identification Number:
002750328

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
6003-05-30094117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.750 INCHES NOMINAL
AVERAGE LIFE RATING IN HOURS250.0
BODY HEIGHT0.820 INCHES NOMINAL
BODY LENGTH2.250 INCHES NOMINAL
BODY WIDTH1.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 3RD RADIO INTERFERENCE
OPERATING TEMP RANGE-55.0 TO 85.0 DEG CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION400.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 120.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION4.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION4.0 VOLTS DC 2ND RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION4.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION400.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 120.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION400.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 120.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL HEIGHT0.820 INCHES NOMINAL
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.0 KILOVOLTS AT SEA LEVEL