5330-00-236-2760 GASKET Index 5950-00-236-2766 REACTOR

National Stock Number:
5915-00-236-2763

Federal Supply Class:
5915

National Item Identification Number:
002362763

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
241-5015-01013499ROCKWELL COLLINS, INC.
JN14-2462B156289SPRAGUE ELECTRIC CO WORLD HQS
JN14-2462C113619EMS DEVELOPMENT CORPORATION


Techincal Specification:
AVERAGE LIFE RATING IN HOURS250.0
BODY HEIGHT4.000 INCHES NOMINAL
BODY LENGTH10.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH4.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH3.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH12.800 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE264.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE45.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.3 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S) SECOND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) FIRST FUNCTION
NOMINAL THREAD SIZE0.250 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS40.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 55.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION132.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
UNTHREADED MOUNTING HOLE DIAMETER0.265 INCHES NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT15.000 POUNDS NOMINAL