5340-00-185-5354 STRAP,RETAINING Index 1650-00-185-5356 CAP,VALVE

National Stock Number:
5915-00-185-5355

Federal Supply Class:
5915

National Item Identification Number:
001855355

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2712-0015-0115280NORTHROP GRUMMAN SYSTEMS CORPORATION DIV ES DEFENSIVE SYSTEMS DIVISION
2712-0015-0126916NORTHROP GRUMMAN SYSTEMS CORPORATION
RF314613619EMS DEVELOPMENT CORPORATION


Techincal Specification:
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMS3102R20-4P
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0