| REFERENCE FREQUENCY PER FUNCTION | 5.25 GIGAHERTZ BLANK |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.25 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | 3.50 GIGAHERTZ BLANK AND |
| 7.00 GIGAHERTZ BLANK |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.35 BLANK |
| INCLOSURE TYPE | ENCASED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
| 1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION |
| STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| OVERALL LENGTH | 2.400 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.500 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 3.50 GIGAHERTZ BLANK AND |
| 7.00 GIGAHERTZ BLANK AND |
| 16.00 GIGAHERTZ BLANK AND |
| 21.00 GIGAHERTZ BLANK |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 0.25 MAXIMUM BLANK AND |
| 60.0 MINIMUM BLANK 1ST FUNCTION |
| INPUT TERMINAL MANUFACTURER CODE | 10001 |
| INPUT TERMINAL IDENTIFICATION | TNCFEMALE |
| OUTPUT TERMINAL MANUFACTURER CODE | 10001 |
| OUTPUT TERMINAL IDENTIFICATION | TNCFEMALE |
| OPERATING TEMP RANGE | -55.0 TO 150.0 DEG CELSIUS |