| AVERAGE POWER RATING PER FUNCTION | 18.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| BODY MATERIAL | ALUMINUM |
| BODY OUTSIDE DIAMETER | 0.450 INCHES MINIMUM AND 0.550 INCHES MAXIMUM |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| FEATURES PROVIDED | NUT |
| FREQUENCY BAND WIDTH PER FUNCTION | 97.50 MEGAHERTZ BLANK AND 102.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OVERALL LENGTH | 7.450 INCHES MINIMUM AND 7.550 INCHES MAXIMUM |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.312 INCHES |
| OPERATING TEMP RANGE | +0.0 TO 85.0 CELSIUS |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| REFERENCE FREQUENCY PER FUNCTION | 100.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 97.5 MEGAHERTZ BLANK AND 102.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 94.40 MEGAHERTZ BLANK AND 97.50 MEGAHERTZ BLANK AND 102.50 MEGAHERTZ BLANK AND 105.60 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |