5915-00-163-6521 FILTER,BAND PASS Index 5915-00-163-6523 FILTER SET,ELECTRICAL MATCHED

National Stock Number:
5915-00-163-6522

Federal Supply Class:
5915

National Item Identification Number:
001636522

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
247ASC0113-00230003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
4LC510KL23042TRILITHIC, INC.


Techincal Specification:
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MAXIMUM BLANK AND 30.0 MINIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION510.00 MEGAHERTZ BLANK AND 650.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMIL-C-39012 SMA PLUG
INPUT TERMINAL MANUFACTURER CODE81349
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONMIL-C-39012 SMA JACK
OUTPUT TERMINAL MANUFACTURER CODE81349
OVERALL LENGTH3.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION580.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 55.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION510.0 MEGAHERTZ BLANK AND 650.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION510.00 MEGAHERTZ BLANK AND 650.00 MEGAHERTZ BLANK AND 720.00 MEGAHERTZ BLANK AND 1.44 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES