| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 0.0 MINIMUM BLANK AND 125.0 MINIMUM BLANK AND 130.0 MINIMUM BLANK FIRST FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 0.00 HERTZ BLANK AND 3.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | ENCASED |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 2.2 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING TEMP RANGE | -55.0 TO 105.0 CELSIUS |
| OUTPUT TERMINAL IDENTIFICATION | 141-0002-0002 |
| OUTPUT TERMINAL MANUFACTURER CODE | 98278 |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.086 INCHES |
| SOURCE IMPEDANCE RATING PER FUNCTION | 2.2 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| REFERENCE FREQUENCY PER FUNCTION | 1.5 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| VIBRATION RESISTANCE RANGE IN HERTZ | +55.0 TO 500.0 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 0.00 HERTZ BLANK AND 3.00 KILOHERTZ BLANK AND 9.90 KILOHERTZ BLANK AND 50.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |