5995-00-134-0290 CABLE ASSEMBLY,RADIO FREQUENCY Index 5915-00-134-0292 FILTER,BAND PASS

National Stock Number:
5915-00-134-0291

Federal Supply Class:
5915

National Item Identification Number:
001340291

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
172AS58230003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
X11BC125-70AA90-23042TRILITHIC, INC.
X11BC125-70AA90-16030003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION2.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION90.00 MEGAHERTZ BLANK AND 160.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE30003
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE30003
OVERALL LENGTH12.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION125.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 55.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION90.0 MEGAHERTZ BLANK AND 160.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION62.00 MEGAHERTZ BLANK AND 90.00 MEGAHERTZ BLANK AND 160.00 MEGAHERTZ BLANK AND 186.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES