5950-00-104-2737 TRANSFORMER,POWER Index 5960-00-104-2740 ELECTRON TUBE

National Stock Number:
5915-00-104-2738

Federal Supply Class:
5915

National Item Identification Number:
001042738

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
6135-101414304L3HARRIS TECHNOLOGIES, INC.
RF02663A13619EMS DEVELOPMENT CORPORATION
RF2663A13619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH5.000 INCHES NOMINAL
BODY WIDTH2.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH5.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMS3102R-20-6
INPUT TERMINAL MANUFACTURER CODE96906
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONMS3102R-20-6
OUTPUT TERMINAL MANUFACTURER CODE96906
OVERALL HEIGHT2.750 INCHES NOMINAL
OVERALL LENGTH6.000 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED HOLE(S) SECOND FUNCTION
NOMINAL THREAD SIZE0.138 INCHES
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
TEST DATA DOCUMENT14304-6135-1014 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)