5905-00-101-2136 RESISTOR,FIXED,WIRE WOUND Index 5905-00-101-2141 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5915-00-101-2138

Federal Supply Class:
5915

National Item Identification Number:
001012138

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
0N175039-798230NATIONAL SECURITY AGENCY
4999-2089-711165TRAK MICROWAVE CORP
4999-2089-712855SMITHS INTERCONNECT INC


Techincal Specification:
BODY HEIGHT0.890 INCHES NOMINAL
BODY LENGTH0.995 INCHES NOMINAL
BODY WIDTH0.595 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND 5.0 MAXIMUM BLANK AND 35.0 MAXIMUM BLANK AND 55.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.590 INCHES MINIMUM AND 0.610 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION5.00 KILOHERTZ BLANK AND 20.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION10.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT10.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.070 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY14 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION10.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.00 KILOHERTZ BLANK AND 20.00 KILOHERTZ BLANK AND 80.00 KILOHERTZ BLANK AND 200.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial