5950-00-097-6296 TRANSFORMER,POWER Index 5930-00-097-6298 SWITCH,ROTARY

National Stock Number:
5915-00-097-6297

Federal Supply Class:
5915

National Item Identification Number:
000976297

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
42619G194117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
BODY HEIGHT1.500 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 WIRE LEAD OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.3 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.3 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
OVERALL LENGTH3.560 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial