5915-00-087-5858 FILTER,BAND PASS Index 5915-00-087-5861 FILTER,BAND PASS

National Stock Number:
5915-00-087-5860

Federal Supply Class:
5915

National Item Identification Number:
000875860

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
293-0721-00013499ROCKWELL COLLINS, INC.


Techincal Specification:
BODY LENGTH2.234 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.550 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LOOP INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LOOP OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE LOOP GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION373.89 KILOHERTZ BLANK AND 380.27 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-62.0 TO 90.0 CELSIUS
OVERALL HEIGHT1.062 INCHES NOMINAL
OVERALL LENGTH2.812 INCHES NOMINAL
OVERALL WIDTH0.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION1.5 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION377.08 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESTERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION177.08 KILOHERTZ BLANK AND 373.89 KILOHERTZ BLANK AND 380.27 KILOHERTZ BLANK AND 577.08 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES