6130-00-074-0140 POWER SUPPLY Index 5930-00-074-0155 ADAPTER,SWITCH ACTUATOR

National Stock Number:
5915-00-074-0142

Federal Supply Class:
5915

National Item Identification Number:
000740142

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
106109456232LOCKHEED MARTIN CORPORATION
248385810001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BODY LENGTH4.920 INCHES NOMINAL
BODY OUTSIDE DIAMETER4.125 INCHES NOMINAL
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONPT06E12-10S
INPUT TERMINAL MANUFACTURER CODE77820
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
OUTPUT TERMINAL IDENTIFICATIONMS3113H12-10P
OUTPUT TERMINAL MANUFACTURER CODE96906
OVERALL LENGTH5.370 INCHES NOMINAL
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.5 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.15 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.15 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.27 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SPECIAL FEATURESEIGHT FUNCTIONS
UNTHREADED MOUNTING HOLE DIAMETER1.937 INCHES NOMINAL
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES