5950-00-069-3871 COIL,ELECTRICAL Index 5915-00-069-3873 FILTER,BAND PASS

National Stock Number:
5915-00-069-3872

Federal Supply Class:
5915

National Item Identification Number:
000693872

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
69044980249BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
F260172149ELECTRONIC TRANSFORMER CORP
FS0693-87256662FREQUENCY SELECTIVE NETWORKS, INC.


Techincal Specification:
BODY HEIGHT1.625 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
BODY LENGTH1.249 INCHES MINIMUM AND 1.312 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.249 INCHES MINIMUM AND 1.312 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND PASS AND 60.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND PASS AND 60.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.234 INCHES MINIMUM AND 1.250 INCHES MAXIMUM
FREQUENCY BAND WIDTH PER FUNCTION7.50 KILOHERTZ 2ND BAND PASS AND 11.80 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION7.50 KILOHERTZ 1ST BAND PASS AND 11.80 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS FIRST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION600.0 OHMS 2ND BAND PASS SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION600.0 OHMS 1ST BAND PASS FIRST FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OVERALL HEIGHT2.125 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND PASS FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION9.4 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION9.4 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS 1ST BAND PASS FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS 2ND BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.35 KILOHERTZ 2ND BAND PASS AND 7.50 KILOHERTZ 2ND BAND PASS AND 11.80 KILOHERTZ 2ND BAND PASS AND 13.95 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.35 KILOHERTZ 1ST BAND PASS AND 7.50 KILOHERTZ 1ST BAND PASS AND 11.80 KILOHERTZ 1ST BAND PASS AND 13.95 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE