5910-00-062-1306 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5310-00-062-1312 WASHER,FLAT

National Stock Number:
5915-00-062-1307

Federal Supply Class:
5915

National Item Identification Number:
000621307

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
569869-196214RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT2.468 INCHES MAXIMUM
BODY LENGTH2.890 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.850 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS45.0 MINIMUM BLANK AND 5.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.690 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.090 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION99.30 KILOHERTZ BLANK AND 100.70 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD12.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATION1
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT12.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT3.018 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE+0.0 TO 75.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION100.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION95.00 KILOHERTZ BLANK AND 99.30 KILOHERTZ BLANK AND 100.70 KILOHERTZ BLANK AND 105.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE