Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
172AS580-230003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
8BE3751250-3-AA23042TRILITHIC, INC.


Techincal Specification:
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER1.000 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 1.5 MAXIMUM BLANK FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION250.00 MEGAHERTZ BLANK AND 500.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATIONNFEMALE
INPUT TERMINAL MANUFACTURER CODE30003
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH7.500 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 CONNECTOR LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 55.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONNFEMALE
OUTPUT TERMINAL MANUFACTURER CODE30003
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION375.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION50.00 MEGAHERTZ BLANK AND 250.00 MEGAHERTZ BLANK AND 500.00 MEGAHERTZ BLANK AND 650.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 55.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION250.00 MEGAHERTZ BLANK AND 500.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED