5905-00-018-8041 RESISTOR,VARIABLE,WIRE WOUND,NON Index 5950-00-018-8043 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5915-00-018-8042

Federal Supply Class:
5915

National Item Identification Number:
000188042

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
21-014456-0115280NORTHROP GRUMMAN SYSTEMS CORPORATION DIV ES DEFENSIVE SYSTEMS DIVISION
21-014456-0126916NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS15.0 NOMINAL 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS15.0 NOMINAL 2ND BAND PASS SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION700.00 MEGAHERTZ BLANK AND 850.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATION4133-0003
INPUT TERMINAL MANUFACTURER CODE95077
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATION8006-1
OUTPUT TERMINAL MANUFACTURER CODE95712
OVERALL LENGTH6.750 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION775.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION670.00 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION880.00 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial