5905-01-445-3495 RESISTOR,FIXED,WIRE WOUND Index 2910-01-445-3497 INJECTOR ASSEMBLY,FUEL

National Stock Number:
5910-01-445-3496

Federal Supply Class:
5910

National Item Identification Number:
014453496

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
34-1522-227192DRS NAVAL POWER SYSTEMS INC
BV20-254A99120PLASTIC CAPACITORS INC
L0471216236DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (VENDOR ITEM DRAWINGS)
LO471216236DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (VENDOR ITEM DRAWINGS)


Techincal Specification:
BODY HEIGHT2.500 INCHES MINIMUM AND 2.610 INCHES MAXIMUM
BODY LENGTH2.080 INCHES MINIMUM AND 2.190 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY WIDTH1.230 INCHES MINIMUM AND 1.340 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.812 INCHES MINIMUM
CRITICALITY CODE JUSTIFICATIONZZZY
DIELECTRIC MATERIALPLASTIC POLYPROPYLENE
FEATURES PROVIDEDHERMETICALLY SEALED CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION2000.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP5.0 CELSIUS MINIMUM AND 90.0 CELSIUS MAXIMUM
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP.
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO4712
TERMINAL DIAMETER0.250 INCHES NOMINAL
TERMINAL HEIGHT FROM BODY1.200 INCHES MINIMUM AND 1.300 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 STANDOFF, THREADED STUD
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial