4130-01-434-2491 FILTER MEDIA,AIR CONDITIONING Index 5930-01-434-2493 SWITCH,PRESSURE

National Stock Number:
5910-01-434-2492

Federal Supply Class:
5910

National Item Identification Number:
014342492

Description:
CAPACITOR,FIXED,METALLIZED,PAPER

Detail:
A capacitor whose capacitance value cannot be adjusted or varied having paper, plastic, or any combination of paper and plastic as the dielectric material with a metallic film deposited thereon. It may be a single unit or consist of two or more units which cannot be separated.


Manufacturer Information:
M39022/10-J103KR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39022/10J104KR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39022/1081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39022/1081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.557 INCHES MINIMUM AND 0.577 INCHES MAXIMUM
BODY LENGTH1.094 INCHES MINIMUM AND 1.156 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
DIELECTRIC MATERIALPLASTIC POLYCARBONATE
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT REFERENCE TEMP250000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION600.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-39022/10 GOVERNMENT SPECIFICATION
TERMINAL LENGTH1.625 INCHES MINIMUM
TERMINAL DIAMETER0.032 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-39022 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION